Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
1.
Asian Spine Journal ; : 928-935, 2019.
Article in English | WPRIM | ID: wpr-785494

ABSTRACT

STUDY DESIGN: Retrospective cohort study (level of evidence: 4).PURPOSE: To demonstrate the effects of balloon kyphoplasty (BKP) on prevention of kyphosis progression.OVERVIEW OF LITERATURE: Kyphoplasty can correct local kyphosis (fractured vertebra), but its efficacy is attenuated by adjacent fracture and/or disc height reduction with endplate damage. With these attenuating factors incorporated, a comparison between BKP and conservative treatment is necessary to verify the effect of BKP on kyphosis correction.METHODS: This study retrospectively analyzed 129 patients treated conservatively and 95 treated with BKP in our institution. The rate of new adjacent fracture occurrence was determined using Kaplan–Meier analysis. We examined the progression of local kyphosis in patients who underwent lateral X-ray after 1 year. Local kyphosis was measured as an angle between higher end plate of the vertebra above and lower end plate of the vertebra below the fractured vertebra. The comparison included 45 patients treated conservatively and 58 treated with BKP.RESULTS: The incidence of new adjacent fracture at 1 year was 7.3% in the conservative treatment group and 23.2% in the BKP group (p<0.001), while the progression of local kyphosis at 1 year was 5.7°±4.7° and 3.2°±4.6°, respectively (p=0.01). Relative to conservative treatment, local kyphosis did not progress after BKP, despite the higher incidence of adjacent fracture. Local kyphosis progressed in cases with adjacent fracture compared with those without adjacent fracture (6.0°±4.3° vs. 2.1°±4.3°, p=0.003), and fractured vertebral instability was found to be a risk factor for adjacent fracture in BKP.CONCLUSIONS: Compared with the conservative treatment, BKP suppressed the progression of local kyphosis. However, an adjacent fracture attenuated the BKP correction and was more frequently seen in patients with unstable vertebral fractures.


Subject(s)
Humans , Cohort Studies , Incidence , Kyphoplasty , Kyphosis , Retrospective Studies , Risk Factors , Spine
2.
Asian Spine Journal ; : 789-793, 2015.
Article in English | WPRIM | ID: wpr-209946

ABSTRACT

Four patients underwent stabilization surgery using both bilateral C2 pedicle screw (PS) and intralaminar screw (LS). Neural and vascular injury resulting from incorrect screw placement was assessed using computed tomography (CT). The evaluation of bone union was assessed by lateral flexion-extension X-ray films and CT. The symptoms were improved in all patients. There were no intraoperative complications. Furthermore, there were no cases of neurological worsening or vascular injury from incorrect screw placement. Failure of instrumentation or screw loosening during the follow-up period did not occur in any of the patients. All cases had accomplished bone union at the final follow-up. Theoretically, the stabilization technique using both bilateral C2 PS and LS at the same time can provide more stability than any other single technique. Simultaneous use of both bilateral C2 PS and LS is potentially a good choice for surgical repair.


Subject(s)
Humans , Follow-Up Studies , Intraoperative Complications , Spinal Fusion , Vascular System Injuries , X-Ray Film
3.
Asian Spine Journal ; : 461-464, 2015.
Article in English | WPRIM | ID: wpr-29566

ABSTRACT

The breakage of an epidural catheter is an extremely rare complication. We describe a unique case where a retained epidural catheter fragment after epidural anesthesia was treated by surgery. The epidural catheter broke during its removal, requiring surgery to remove the retained catheter. Intraoperatively, the removal of the catheter was attempted by simple traction, but was impossible because of the adhesion. The adhesion of the dura mater surface was carefully exfoliated and the successful removal of the catheter was accomplished. Conventionally, it was said that this follow-up was enough for the retained catheter. However, if a catheter is retained within the spinal canal, surgical removal should thus be considered before the adhesion advances.


Subject(s)
Anesthesia, Epidural , Catheters , Dura Mater , Follow-Up Studies , Spinal Canal , Traction
4.
Asian Spine Journal ; : 69-73, 2014.
Article in English | WPRIM | ID: wpr-178765

ABSTRACT

The posterior epidural migration of lumbar disc fragments is an extremely rare event with an unknown pathogenesis. To the best of our knowledge, there are no previously reported cases of a change of ordinary disc herniation into the posterior epidural migration of lumbar disc fragments as confirmed by magnetic resonance imaging (MRI). A 26-year-old male presented to our department complaining of left buttock and lateral leg pain. An ordinary herniation was shown in the first MRI. The patient's unilateral symptoms changed into bilateral symptoms while awaiting admission to the hospital. Posterior migrated lumbar disc fragments were shown in the second MRI taken at the time of admission. Microendoscopic surgery providing a detailed observation of the region was performed. Our case indicates that an ordinary lumbar disc herniation may lead to the posterior migration of lumbar disc fragments, and that microendoscopic surgery may provide a treatment.


Subject(s)
Adult , Humans , Male , Buttocks , Endoscopy , Hernia , Leg , Magnetic Resonance Imaging
5.
Asian Spine Journal ; : 190-195, 2013.
Article in English | WPRIM | ID: wpr-108265

ABSTRACT

STUDY DESIGN: Case series. PURPOSE: The aim of this study was to describe translaminar microendoscopic herniotomy (TL-MEH) for cranially migrated lumbar disc herniations encroaching on the exiting nerve root in the preforaminal and foraminal zones and to report preliminary results of the procedure. OVERVIEW OF LITERATURE: Conventional interlaminar approaches for preforaminal and foraminal lumbar disc herniations result in extensive removal of the lamina and facet joint to remove disc fragments safely. More destructive approaches increase the risk of postoperative segmental instability. METHODS: TL-MEH is a minimally invasive procedure for herniotomy via the translaminar approach using a microendoscopic technique. TL-MEH was performed in seven patients with a cranially migrated lumbar disc herniation encroaching on the exiting nerve root. The disc fragments were located in the preforaminal zone in four patients, and in the preforaminal and foraminal zones in three. RESULTS: All patients experienced immediate relief from symptoms after surgery and satisfactory results at the final follow-up. Surgical complications, such as a dural tear, nerve injury, and surgical site infection, were not investigated. CONCLUSIONS: TL-MEH seemed to be an effective and safe alternative minimally invasive surgical option for patients with a cranially migrated lumbar disc herniation encroaching the exiting nerve root in the preforaminal and foraminal zones.


Subject(s)
Humans , Follow-Up Studies , Zygapophyseal Joint
SELECTION OF CITATIONS
SEARCH DETAIL